Vue de la page 0
INSTALLATION AND
OPERATION MANUAL
Safety Vacuum Release System (or SVRS) may prevent full body entrapment; SVRS does not protect
against hair entrapment, mechanical entrapment, limb entrapment and/or evisceration.
Jandy Pro Series
ePump
+ SVRS
H0414300 Rev C
ENGLISH
|
FRANÇAIS | ESPAÑOL
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Jandy Pro Series

INSTALLATION AND OPERATION MANUALSafety Vacuum Release System (or SVRS) may prevent full body entrapment; SVRS does not protect against hair entrapmen

Page 2 - Table of Contents

WARNINGTo prevent full-body entrapment, the system must be built so it cannot operate with the pump drawing water from only one (1) suction outlet. At

Page 3 - 1.1 Safety Instructions

supply. Do not ground to a gas supply line.2. Wire size must be adequate to minimize voltage drop during the start-up and operation of the pump. See

Page 4 - w/SVRS

WARNINGELECTRICAL SHOCK HAZARDTurn off all switches and the main breaker in the ePump electrical circuit before starting the procedure. Failure to com

Page 5

6. Select the desired address(es) for the ePump + SVRS(s) by setting dip switches 3 and/or 4, as shown in Section 3.3, ePump + SVRS Dip Switch Settin

Page 6 - SAVE THESE INSTRUCTIONS

Contact ClosureFrom a stopped condition, there is a three-minute delay before the Aux Load contact is closed when the motor speed reaches and maintain

Page 7

Lid with Locking Ringand SealBluePressureTest O-ringPump DebrisTrap Basket(Inside Pump) (Note: Discardafter pressure test is complete.) Figure 10. Ex

Page 8 - Preparation Information

3.6 Conducting Pressure Test WARNINGWhen pressure testing a system with water, air is often trapped in the system during the filling process. This ai

Page 9 - Pump Location

NOTE Do not use petroleum based lubricants or sealants on the lid o-ring. 4. Hand-tighten the lid to make an air tight seal. Do not use any tools to

Page 10 - Installation Recommendations

3. Keep the motor covered and dry. Do not cover the pump with plastic, because this will create condensation that will damage the pump.NOTE Zodiac P

Page 11 - Electrical Wiring

6.2 TroubleshootingSymptom Possible Cause/SolutionThe cleaning/circulating system is not operating correctly.Verify that skimmer baskets, pump filter

Page 12 - PDA or AquaLink Z4 to ePump

Table of ContentsSection 1. Important Safety Instructions ... 31.1 Safety Instructions ... 31.2 Pool Pump Su

Page 13 - F1015 F1014

Symptom Possible Cause/SolutionPump will not start. No power to pump.Make sure pump is properly connected to high voltage. See Section 3.2, Electrical

Page 14 - Pro Series ePump

Section 7. Product Specifications and Technical DataKey No. Description Part No.1 Motor w/Drive, ePump + SVRS Series R05622052 Backplate, Pump, SHP, P

Page 15 - Replace Blue O-ring

Figure 9. ePump + SVRS Exploded View212, 5342, 143, 16, 244 (Qty 2)16 (Qty 2) 13 1215114, 16610 (Qty 2)8 915117 (Qty 2)1 (Qty 2)72 (Qty 8)17 (Qty 8)1

Page 16 - Section 4. Operation

7.2 Performance Curves01020304050607080901001101200 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 2500510152

Page 17 - 5.2 Winterizing the Pump

Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 | www.ZodiacPoolSystems.comZodiac Pool Systems Canada, Inc. 2115 South S

Page 18 - Blocked Impeller

Section 1. IMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONS1.1 Safety InstructionsAll electrical work must be performed by a licensed e

Page 19 - 6.2 Troubleshooting

WARNINGTo reduce the risk of injury, do not permit children and/or adults not familiar and experienced with the operation of swimming pool pumps to

Page 20

WARNINGThe Jandy Pro Series ePump + SVRS is capable of generating system pressures up to 50 psi. Installers must ensure that all system components a

Page 21

WARNINGThe Jandy Pro Series ePump + SVRS has been designed to operate with Zodiac® control systems. Operating the pump with other manufacturers&apos

Page 22

WARNINGWater Velocity - The maximum water velocity through the suction outlet assembly and its cover for any suction outlet must not exceed the sucti

Page 23 - Dimensions

Section 2. General Description2.1 IntroductionThis manual contains information for the proper installation, operation, and maintenance of Jandy Pro Se

Page 24 - NSF/ANSI Standard 50

NOTE In Canada the minimum distance maintained from the edge of the pool and/or spa as noted above must be 3m (10 feet), as required by the Canadian